One Nokia AirScale ABIA (473096A) capacity card is enough for most single-layer or dual-layer LTE macro sites. According to the Nokia datasheet, one ABIA handles up to 12 LTE cells at 2T2R 20 MHz or 6 cells at 4T4R 20 MHz, with 6 SFP+ fronthaul ports. A second ABIA is usually needed when you add more carriers, move to 4T4R on several layers, or simply run out of fibre ports for the radios. This guide explains how to size an AirScale System Module card by card, with worked examples.
How AirScale capacity is built
The AirScale System Module Indoor is modular. The Nokia AMIA subrack provides the backplane, power and cooling, and has 2 slots for common units and 6 slots for capacity units. The work is split between two card types:
- Common unit (ASIA or ASIB): control plane, transport (backhaul) and synchronisation.
- Capacity unit (ABIA, or ABIO on newer configurations): baseband processing and the optical fronthaul connections to the radio units.
The minimum configuration is one common unit plus one ABIA. The maximum in one AMIA is two common units plus six ABIA cards. So capacity planning is really a question of how many ABIA cards you install, and whether one common unit is enough for the transport and control load.
Nokia ABIA capacity figures
The table below summarises the per-card figures from Nokia’s ABIA technical datasheet. Nokia notes that capacity, performance and features depend on the software release, configuration and traffic model, so treat these as hardware limits rather than guaranteed values for every network.
| Item | Per ABIA (473096A) |
|---|---|
| Fronthaul ports | 6 x SFP+ (CPRI up to 9.8 Gbps, OBSAI 3/6 Gbps) |
| IQ compression | Supported on 3 of the 6 CPRI 9.8G interfaces |
| LTE cells, 2T2R 20 MHz | 12 |
| LTE cells, 2T2R 10 MHz | 16 |
| LTE cells, 4T4R 20 MHz | 6 |
| RRC users | 5,040 |
| L1 throughput DL/UL | 1.8 Gbps / 0.9 Gbps |
| WCDMA capacity | 12 cells |
| GSM capacity | 36 TRX |
| Supported subracks | AMIA, AMOB, AMOD |
Early AirScale software was more conservative. Nokia material for the first release quotes 8 LTE 20 MHz 2×2 MIMO cells per ASIA + ABIA pair, rising to 48 cells for a full 2 ASIA + 6 ABIA module. If you are buying used cards for a network that runs an older release, check what that release actually supports before planning on 12 cells per card.
System module configurations at a glance
Nokia’s AirScale System Module Indoor datasheet (with ASIB as the common unit) gives these LTE capacities and power figures for typical card counts:
| Configuration | LTE capacity (20 MHz, 4 antennas) | Typical / max power |
|---|---|---|
| 1 ASIB + 1 ABIA | 6 cells | 190 W / 327 W |
| 1 ASIB + 3 ABIA | 18 cells | 400 W / 596 W |
| 2 ASIB + 6 ABIA | 36 cells | 790 W / 1,248 W |
The power column matters when you reuse an existing cabinet: size the DC supply and breakers for the final card count, not just the first card you install.
Step-by-step: sizing ABIA cards for a site
1. Count the cells
Multiply sectors by carriers (layers) for each technology. A 3-sector site with LTE on three bands has 9 LTE cells. Note the MIMO mode and bandwidth of each cell, because a 4T4R 20 MHz cell uses roughly twice the baseband resources of a 2T2R 20 MHz cell on the ABIA.
2. Count the fronthaul links
Each ABIA has 6 SFP+ ports. Every radio unit needs its own optical link unless your configuration uses multi-band radios or another supported way of sharing links. On sites with many single-band radios, the port count often decides the number of ABIA cards before the cell count does.
3. Check licences
ABIA capacity is activated by hardware activation (HWA) licences. In Nokia’s AirScale material, one HWA activates half of an ABIA, and two are needed for a full card. When you add a used ABIA to a live network, make sure the licence pool covers it.
4. Decide on one or two common units
A second common unit is used for high-capacity configurations or to run two independent base stations in one subrack. Nokia notes that adding a second common unit does not increase transport capacity, so plan backhaul separately. The ASIA and ASIB both provide 3 x 1GE electrical and 2 x 10GE optical backhaul ports. For the differences between them, see our article on Nokia AirScale ASIA vs ASIB.
Worked examples
| Site profile | Cells | Radio links | Suggested ABIA count |
|---|---|---|---|
| 3 sectors, 1 LTE layer, 2T2R 20 MHz | 3 | 3 | 1 |
| 3 sectors, 2 LTE layers, 4T4R 20 MHz | 6 | 6 (single-band radios) | 1, at its limit |
| 3 sectors, 3 LTE layers, 2T2R 20 MHz | 9 | 9 (single-band radios) | 2 (port count, not cells) |
| 3 sectors, 3 LTE layers, 4T4R 20 MHz | 9 | 9 | 2 |
These examples assume the current datasheet figures and single-band radios. Always confirm the final layout against your software release and the radio models you use. Leaving headroom for one extra card slot is good practice, since adding a later carrier only requires another ABIA in the same AMIA.
When ABIO is the better choice
The Nokia ABIO (475266A) is a higher-capacity LTE/5G NR card. Its datasheet lists up to 48 narrowband cells (2T2R or 4T4R) and 5G NR wideband support, but it works with the ASIB and ASIL common units, not the ASIA. If your plan includes 5G NR or many 4T4R layers, compare both cards first. Our article Nokia ABIA vs ABIO covers the differences in detail.
Tips when adding used ABIA cards
- Confirm the product code (473096A) and revision on the label.
- Check all six SFP+ cages for damage and make sure you have the right optical modules for each link.
- Fit blanking plates in empty slots so the AMIA airflow stays correct.
- Plan DC power for the full card count, using the power figures above.
- Make sure the software release on the site supports the card revision you are adding.
FAQ
How many ABIA cards fit in one AMIA?
Up to six, together with one or two common units.
Does a second ASIA or ASIB double backhaul capacity?
No. Nokia states that a second common unit does not increase transport capacity. It is used for high-capacity configurations or independent base stations in the same subrack.
Can one ABIA run GSM, WCDMA and LTE?
The ABIA is multi-RAT hardware, and Nokia lists mixed modes such as GSM/WCDMA, WCDMA/LTE and GSM/LTE. Whether a mix works on your site depends on the software release and licences.
Why can 6 cells be the limit on one ABIA?
Because 4T4R 20 MHz cells use more baseband resources. The datasheet gives 6 cells at 4T4R 20 MHz, compared with 12 at 2T2R 20 MHz.
Get tested Nokia AirScale cards
We supply the Nokia ABIA, ASIA, ASIB, ABIO and AMIA, along with Flexi and AirScale radio units in our Nokia product range. Every unit is functionally tested before shipment (radio units such as RRUs are also VSWR tested), comes with a 90-day warranty, and is shipped worldwide in secure packaging. Contact us on WhatsApp at +86 187 3329 4669 or +86 139 3088 8705, email jack@telecombts.com, or use the form on our contact page.