The Ericsson Baseband 6648 and the RAN Processor 6651 look almost identical on paper: both are 1U, 19-inch indoor units for LTE and 5G NR, both have 12 SFP-based radio ports that run CPRI or eCPRI at up to 25G, and both use the same TN/IDL transport layout. The real differences are the product generation and number (KDU 137 0015/11 vs KDU 137 0093/11), the power and fuse requirements, and which software release each hardware revision needs. For a replacement or expansion, the safest choice is usually the model that is already in your network.
This article compares the two units side by side using the published Ericsson hardware data, explains where they differ in practice, and lists what to check before buying either one used.
Quick comparison: Baseband 6648 vs RAN Processor 6651
The figures below come from the product descriptions of each unit. Capacity (cells, carriers, users, throughput) is set by configuration, software and licences, so Ericsson does not list it as a fixed hardware figure.
| Item | Baseband 6648 | RAN Processor 6651 |
|---|---|---|
| Product number | KDU 137 0015/11 | KDU 137 0093/11 |
| Product family | Ericsson RAN Compute (Baseband series, launched June 2020) | Ericsson RAN Compute (RAN Processor series) |
| Radio access technologies | LTE, NR, LTE + NR mixed mode | LTE and NR |
| Radio ports | 12 (A to M), SFP / SFP+ / SFP28 | 12 (A to M), SFP28 |
| CPRI line rates | 2.5, 4.9, 9.8, 10.1, 24.3 Gbps | 2.5, 4.9, 9.8, 10.1, 24.3 Gbps |
| eCPRI line rates | 10.3 and 25G class (software dependent) | 10.3 and 25G class |
| TN/IDL A | 1 x QSFP+/QSFP28, 4 x 10 or 4 x 25 GbE | 1 x QSFP28, 4 x 10 or 4 x 25 GbE |
| TN/IDL B, C, D | 3 x SFP/SFP+/SFP28, 1/10/25 GbE | 3 x SFP28, 1/10/25 GbE |
| TN E | 1 x RJ45, 100 Mbps / 1 GbE | 1 x RJ45, 100 Mbps / 1 GbE |
| Power input | -48 V DC, dual input with failover | -48 V DC, dual input with redundancy |
| External fuse | 16 A minimum, 20 A maximum | 15 A minimum, 25 A maximum |
| Form factor | 1U, 19-inch, 352 mm deep | 1U, 19-inch, 352 mm deep (383 mm with protrusions) |
| Operating temperature | 0 to +55 °C (R2C/R2D revisions: 0 to +45 °C) | 0 to +55 °C |
| Environment | Indoor, IP20 | Indoor, IP20 |
What the two units have in common
Same radio interface concept
Both units have twelve radio ports lettered A to M, and both support CPRI and eCPRI on all of them. The CPRI line rates are the same, from 2.5 Gbps up to 24.3 Gbps, and both offer 25G-class eCPRI for packet-fronthaul radios. In practice this means the same types of Ericsson radios can be connected to either unit, provided the software release supports the radio and the correct SFP modules are fitted. Optical modules are normally ordered separately from the baseband.
Same transport layout
The transport side is also laid out the same way: one QSFP port (TN/IDL A) for 4 x 10 or 4 x 25 GbE, three SFP ports (TN/IDL B to D) for 1, 10 or 25 GbE, and one RJ45 port (TN E) for 100 Mbps or 1 GbE. The TN/IDL ports can carry backhaul or be used as baseband-to-baseband links on larger sites. Both units also have RJ45 ports for GNSS sync, external alarms and local management (LMT).
Same physical footprint
Both are 1U, 19-inch rack units for indoor use (IP20) and run on -48 V DC with two power inputs. A rack position that fits one will fit the other, which is why the two are easy to confuse in a spares store.
Where they differ
1. Generation and product number
Ericsson launched the Baseband 6648 in June 2020 as a next-generation baseband for LTE and 5G NR, quoting up to three times the capacity of its existing basebands at that time and peak throughput of 10 to 15 Gbps downlink and 3 Gbps uplink. Ericsson described it as suited to 5G sites in low and mid bands. The RAN Processor 6651 belongs to the later RAN Processor naming in the same RAN Compute portfolio; Ericsson now lists the RAN Processor 6655 as its successor.
The most reliable way to tell them apart is the label. The 6648 carries KDU 137 0015/11 and the 6651 carries KDU 137 0093/11. Do not rely on the front panel alone, because the port layouts are very similar. Our guide to Ericsson baseband KDU numbers explains how to read the full label, including the R-state.
2. Power and fuse rating
The 6648 datasheet gives typical power consumption of about 310 W and a maximum of about 340 W (fan included, SFP and GPS excluded), with a recommended external fuse of 16 to 20 A. The 6651 product description specifies a minimum fuse of 15 A and a maximum of 25 A. When you swap one unit for the other, check that the site’s breaker or fuse matches the unit you are installing.
3. Hardware revisions and software requirements
Revision matters on both units. On the 6648, the R2C and R2D revisions have a narrower operating temperature range (0 to +45 °C instead of +55 °C) and roughly 10% higher power consumption. On the 6651, the R3C revision requires software release 21.Q4.2, 22.Q1.1, 22.Q2.1 or later. Buying the right model with the wrong R-state can mean a unit that does not suit a hot site, or that will not run on your current software.
4. Network fit
Because capacity and features are set by software and licences, neither unit is “better” in isolation. What decides the choice is what your network already runs. Replacing a failed 6648 with another 6648 keeps configuration, software and spares simple. The same applies to the 6651. Mixing models on a site or across a cluster is possible in many networks, but it should be treated as an engineering decision and checked against your software release, not as a simple hardware swap.
Which one should you buy?
- Like-for-like replacement: buy the same model and, where possible, a compatible R-state to the unit being replaced.
- Expanding an existing cluster: match the model already used at neighbouring sites to keep software and spares aligned.
- Hot or poorly cooled sites: if you choose a 6648, avoid R2C/R2D revisions unless the site stays within +45 °C.
- Older software releases: if you choose a 6651, check the R-state against your software release before ordering.
- Older sites: if your network is still built on the Ericsson Baseband 6630, our comparison Baseband 6630 vs 6648 covers that upgrade step.
What to check before buying a used 6648 or 6651
- Label photo: product number, R-state and serial number, clearly readable.
- Ports: SFP and QSFP cages free of bent springs or damage, RJ45 ports intact, dust caps fitted.
- Power: both -48 V DC inputs working, connectors free of burn marks or corrosion.
- Fan and airflow: fan runs normally and the air path is clean.
- Boot and alarms: unit starts with normal LED status and no hardware alarms.
- Accessories: confirm whether SFP modules or power cables are included.
- Licences: hardware does not carry your network’s licences; plan these separately.
FAQ
Are the Baseband 6648 and RAN Processor 6651 interchangeable?
They share the same form factor, port layout and line rates, but they are different products with different product numbers and software requirements. Check your software release, licences and network configuration before replacing one with the other.
Do both support eCPRI radios?
Yes. Both have 12 radio ports that support CPRI and eCPRI, with 25G-class eCPRI available depending on the software package.
How can I tell a 6648 from a 6651 on site?
Read the product label. The Baseband 6648 is KDU 137 0015/11 and the RAN Processor 6651 is KDU 137 0093/11. The front panels look very similar.
Do they support 5G NR?
Yes. Both support LTE and 5G NR. Which features you can use depends on the installed software and licences.
Buy tested Ericsson basebands
We supply the Ericsson Baseband 6648, the Ericsson RAN Processor 6651, the Baseband 6631 and other units in our Ericsson product range. Every unit is functionally tested before shipment (radio units such as RRUs are also VSWR tested), comes with a 90-day warranty, and is shipped worldwide in secure packaging. Send us the model, product number and quantity on WhatsApp +86 187 3329 4669 / +86 139 3088 8705, email jack@telecombts.com, or use the form on our contact page.
We also buy surplus Huawei, Ericsson and Nokia equipment. See sell your equipment.